If you are concerned about the residual water on the roof top terrace, be sure to read this article. We will explain everything from scratch.
The first and most important reason for water on the roof top terrace retention on it’s surface is uneven ground or improper slopes.
If it is the fault of the unevenness of the ground, it is no wonder that the water in the roof top terrace areas. It is not dependent on the top cladding. The fault is in the floor. And it is from its alignment that repairs should begin.
The second possible reason is the poor quality of the finishing elements, i.e. boards or tiles.
If the terrace base has been properly prepared and the edges of the tiles are bent upwards or the boards are boat-like, the fault is on their side.
The cladding needs to be changed. This will solve our problem.
Third, remember that each material has its own strength.
The strength of a component is a numerical value for the weight of pressure that the material can withstand until it fails. The strength value is always provided by the manufacturer.
Often, the lack of knowledge of the value of the maximum weight that can be set on our deck's finishing surface causes damage to it.
The ceramic tiles break and the boards bend. Often even irreversible damage that necessitates replacement with new ones.
Fourthly, the most important thing is to choose the right type of adjustable pedestals for the planned loads.
If we know where we want to place heavy pots, grill or even a pool. It is good to strengthen these places.
Reinforcements are made by additional positioning of the adjustable pedestals. In this way, we will make another adjustable pedestals for the wooden or composite boards or ceramic tiles. And thus strengthen their strength.
The fifth and last important point to pay attention to.
The one that causes the water on the roof terrace to remain in inappropriate places are all the side elements of the structure
Maintaining all technical parameters of adjustable plinths will ensure the correct leveling of each terrace surface. And a balcony. Also, there is no stagnation of water on tiles, boards or terrace ceramic tiles. Of course, everything is in accordance with the montage instructions.
First of all, if the water stagnation on the ventilated terrace is caused only by the unevenness of the boards? Secondly, maybe it's the rustic nature of the boards?
The system of ventilated terraces makes it possible to adjust the height at any time.
However, if you have located the problem and it is in the construction, repair the problem immediately.
This can damage the entire structure of the terrace as a result in the future, its destruction.